Automatic Control Equipment by Emerson

Automatic Control Equipment by Emerson

EX series
TI/TIE/TILE type expansion valve
(Temperature type expansion valve / interchangeable cages)
T series expansion valve
(Temperature type expansion valve / take-apart type)
100RB solenoid valve
(Direct-acting two-way solenoid valve)
200RB solenoid valve
(Pilot-operated two-way solenoid valve)
240RA solenoid valve
(Pilot-operated two-way solenoid valve)
AMG electromagnetic coil
(Solenoid valve coil)
EK dryer
(Dryer for liquid line)
BFK dryer
(Bi-directional/byflow)
ASF suction filter
(Suction line filter)
STAS-T/STAS-SV
(Dryer with interchangeable core)
Dryer filter core
(Dryer with interchangeable core)
AMI sight glass
(Moisture detector)≈
PT5 pressure transmitter
(Pressure converter)
AAS accumulator
(Liquid separator)
AWZ oil separator
(Oil separator)
OM3/OM4/OM5
(Oil level controller)

Temperature Type Expansion Valve (Basic Terms, Technical Materials, Capacity Guide, Correction Factors)

Temperature type expansion valve lowers the pressure of the liquid refrigerant leaving the condenser to a level where the refrigerant is evaporated easily, and ensures an optimal flow rate of the evaporator. According to the capacity of the compressor changing with increase/decrease of the cooling load, the valve maintains the superheat level of the refrigerant gas within a specified range to prevent excessive heating and liquid back flow. Basic terms, technical materials, capacity guide, correction factors of the capacity and other information of the temperature type expansion valves are described in the catalog. Please refer to the catalog for details.

What Is a Solenoid Valve? (Basic Terms, Technical Materials, Correction Factors)

Solenoid valves are opened or closed by using a principle that the plunger is lifted from the valve seat when current is applied, and the plunger returns to the valve seat when current is shut off. The working principles are mainly two types: direct- acting type and pilot- operated type. The direct- acting valve is opened when electromagnetic force lifts the plunger from the valve seat directly. The pilot-operated valve is raised by the fluid pressure of the refrigerant (differential pressure). Electromagnetic force is used only to open the valve seat. Basic terms, technical materials, capacity correction factors and other information of the solenoid valves are described in the catalog. Please refer to the catalog for details.

About Dryer

Dryers are available in two types: Liquid line dryer and suction line filter dryer. The liquid line dryer mainly removes water and foreign substances to prevent block or obstruction of the expansion valve. The suction line filter dryer mainly removes foreign substances to prevent damage of the compressor. EMERSON provides the dryers to be brazed directly on the pipe and the dryers with interchangeable cores that allow the internal drying agents to be replaced after being brazed. Functions of the dryers, selection guide and other information are described in the catalog. Please refer to the catalog for details.